Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Adhes Dent ; 26(1): 41-52, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38329119

RESUMO

PURPOSE: This study aimed to investigate the bonding effectiveness of two HEMA/BPA-free universal adhesives (UAs) to flat dentin, to characterize their adhesive-dentin interfacial ultrastructure, and to measure their water sorption (Wsp), water solubility (Wsl), and hydrophobicity. MATERIALS AND METHODS: The immediate and aged (50,000 thermocycles) microtensile bond strength (µTBS) to flat dentin of the HEMA/BPA-free UAs Healbond Max (HbMax; Elsodent) and Healbond MP (HbMP; Elsodent) as well as the reference adhesives OptiBond FL (Opti-FL; Kerr), Clearfil SE Bond 2 (C-SE2; Kuraray Noritake), and Scotchbond Universal (SBU; 3M Oral Care) was measured. The adhesive-dentin interfaces of HbMax and HbMP were characterized by TEM. Wsp and Wsl of all adhesive resins and of the primer/adhesive resin mixtures of HbMax, Opti-FL, and C-SE2 were measured. Hydrophobicity was determined by measuring the contact angle of water dropped on adhesive-treated dentin. RESULTS: In terms of µTBS, HbMax and HbMP performed statistically similarly to Opti-FL and C-SE2, but outperformed SBU. Aging only significantly reduced the µTBS of SBU when applied in E&R bonding mode. TEM revealed typical E&R and SE hybrid-layer ultrastructures at dentin, while electron-lucent globules of unknown origin, differing in size and shape, were observed within the adhesive resin of HbMP and even more frequently in that of HbMax. Higher Wsp was measured for the primer/adhesive resin mixtures than for the adhesive resins. Opti-FL was more hydrophobic than all other adhesives tested. CONCLUSION: The HEMA/BPA-free UAs bonded durably to flat dentin with bond strengths comparable to those of the gold-standard E&R/SE adhesives and superior to that of the HEMA/BPA-containing 1-step UA.


Assuntos
Colagem Dentária , Cimentos Dentários , Adesivos Dentinários/química , Teste de Materiais , Resistência à Tração , Dentina , Cimentos de Resina/química , Água , Adesivos , Resinas Compostas
2.
Small ; : e2310251, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38362704

RESUMO

Dental adhesives are widely used in daily practice for minimally invasive restorative dentistry but suffer from bond degradation and biofilm attack. Bio-inspired by marine mussels having excellent surface-adhesion capability and high chemical affinity of polydopamine (PDA) to metal ions, herein, experimental zinc (Zn)-containing polydopamine-based adhesive formulation, further being referred to as "Zn-PDA@SiO2 "-incorporated adhesive is proposed as a novel dental adhesive. Different Zn contents (5 and 10 mm) of Zn-PDA@SiO2 are prepared. Considering the synergistic effect of Zn and PDA, Zn-PDA@SiO2 not only presents excellent antibacterial potential and notably inhibits enzymatic activity (soluble and matrix-bound proteases), but also exhibits superior biocompatibility and biosafety in vitro/vivo. The long-term bond stability is substantially improved by adding 5 wt% 5 mm Zn-PDA@SiO2 to the primer. The aged bond strength of the experimentally formulated dental adhesives applied in self-etch (SE) bonding mode is 1.9 times higher than that of the SE gold-standard adhesive. Molecular dynamics calculations indicate the stable formation of covalent bonds, Zn-assisted coordinative bonds, and hydrogen bonds between PDA and collagen. Overall, this bioinspired dental adhesive provides an avenue technology for innovative biomedical applications and has already revealed promising perspectives for dental restorative dentistry.

3.
J Adhes Dent ; 25(1): 241-256, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37975313

RESUMO

PURPOSE: To investigate the bonding performance of three universal adhesives (UAs) to dentin and the effect of different curing modes and hydrofluoric-acid (HF) etching of lithium-disilicate glass-ceramic on the adhesive performance of two UA/composite cement (CC) combinations. MATERIALS AND METHODS: In the first project part, the immediate and aged (25k and 50k thermocycles) microtensile bond strength (µTBS) of the two light-curing UAs G2-Bond Universal (G2B; GC) and Scotchbond Universal Plus (SBUp; 3M Oral Care), and the self-curing UA Tokuyama Universal Bond II (TUBII; Tokuyama) to flat dentin was measured, when applied in both E&R and SE bonding mode using a split-tooth design (n = 10). The resultant adhesive-dentin interfaces were characterized using TEM. In the second project part, CAD/CAM composite blocks were luted to flat dentin with either Scotchbond Universal Plus/RelyX Universal (SBUp/RxU; 3M Oral Care) or Tokuyama Universal Bond II/Estecem II Plus (TUBII/ECIIp; Tokuyama Dental) using different curing modes (AA mode: auto-curing of both adhesive and cement; AL mode: auto-curing of adhesive and light-curing of cement), upon which their immediate and aged (25k and 50k thermocycles) µTBS was measured. In the third project part, the same UA/CC combinations were luted to CAD/CAM glass-ceramic to measure their immediate and aged (6-month water storage) shear bond strength (SBS). RESULTS: In E&R bonding mode, the performance of G2B, SBUp and TUBII was not significantly different in terms of µTBS, while G2B and SBUp significantly outperformed TUBII in SE bonding mode. No significant difference in µTBS was found between the SBUp/RxU and TUBII/ECIIp UA/CC combinations, regardless of bonding mode, aging time, or curing mode. The cement-curing mode did not significantly influence µTBS, while a significantly higher µTBS was recorded for the UA/CC combinations applied in E&R bonding mode. HF significantly improved the SBS of the UA/CC combinations to glass-ceramic. CONCLUSION: The self-curing adhesive performed better when applied in E&R than in SE bonding mode. The curing mode did not influence the adhesive performance of the composite cements, while an E&R bonding mode rendered more favorable adhesion in a self-curing luting protocol. When bonding to glass-ceramic, the adhesive performance of the universal adhesive/composite cement combinations benefited from HF etching.


Assuntos
Colagem Dentária , Cimentos Dentários , Cimentos Dentários/química , Cimentos de Resina/química , Colagem Dentária/métodos , Cimentos de Ionômeros de Vidro , Teste de Materiais , Resistência à Tração , Adesivos Dentinários/química , Adesivos , Dentina
4.
Curr Opin Oncol ; 35(6): 522-528, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37681417

RESUMO

PURPOSE OF REVIEW: Glioblastoma (GBM), the most prevalent primary brain malignancy in adults, poses significant challenges in terms of treatment. Current therapeutic strategies for GBM patients involve maximal safe resection, followed by radiotherapy with concurrent and adjuvant temozolomide. However, despite this multimodal approach for GBM, the prognosis of GBM patients remains dismal because of their inherent primary and secondary resistances to treatments. RECENT FINDINGS: Several molecular and cellular mechanisms, including the presence of the blood-brain barrier (BBB), contribute to these resistances. The BBB, comprising multiple layers surrounding brain vessels, acts as a barrier limiting effective drug delivery to the brain. Invasive and noninvasive tools to deliver drugs and pharmaceutical formulations locally or systemically are continuously evolving to overcome the BBB in GBM toward improving drug bioavailability in the brain and reducing systemic toxicities. SUMMARY: Preliminary studies utilizing these approaches have demonstrated promising results in terms of safety and signals of efficacy during early-phase clinical trials. However, further work through additional clinical trials is necessary to evaluate the potential clinical benefits for GBM patients.

5.
J Neurooncol ; 163(2): 327-338, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37237151

RESUMO

BACKGROUND: Glioblastoma (GBM) is an aggressive brain cancer that typically results in death in the first 15 months after diagnosis. There have been limited advances in finding new treatments for GBM. In this study, we investigated molecular differences between patients with extremely short (≤ 9 months, Short term survivors, STS) and long survival (≥ 36 months, Long term survivors, LTS). METHODS: Patients were selected from an in-house cohort (GLIOTRAIN-cohort), using defined inclusion criteria (Karnofsky score > 70; age < 70 years old; Stupp protocol as first line treatment, IDH wild type), and a multi-omic analysis of LTS and STS GBM samples was performed. RESULTS: Transcriptomic analysis of tumour samples identified cilium gene signatures as enriched in LTS. Moreover, Immunohistochemical analysis confirmed the presence of cilia in the tumours of LTS. Notably, reverse phase protein array analysis (RPPA) demonstrated increased phosphorylated GAB1 (Y627), SRC (Y527), BCL2 (S70) and RAF (S338) protein expression in STS compared to LTS. Next, we identified 25 unique master regulators (MR) and 13 transcription factors (TFs) belonging to ontologies of integrin signalling and cell cycle to be upregulated in STS. CONCLUSION: Overall, comparison of STS and LTS GBM patients, identifies novel biomarkers and potential actionable therapeutic targets for the management of GBM.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Humanos , Idoso , Glioblastoma/patologia , Prognóstico , Neoplasias Encefálicas/patologia , Encéfalo/patologia , Sobreviventes
6.
Pharmaceutics ; 15(2)2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36839777

RESUMO

Therapeutic antibodies targeting immune checkpoints have shown limited efficacy in clinical trials in glioblastoma (GBM) patients. Ultrasound-mediated blood-brain barrier opening (UMBO) using low-intensity pulsed ultrasound improved drug delivery to the brain. We explored the safety and the efficacy of UMBO plus immune checkpoint inhibitors in preclinical models of GBM. A blood-brain barrier (BBB) opening was performed using a 1 MHz preclinical ultrasound system in combination with 10 µL/g microbubbles. Brain penetration of immune checkpoint inhibitors was determined, and immune cell populations were evaluated using flow cytometry. The impact of repeated treatments on survival was determined. In syngeneic GL261-bearing immunocompetent mice, we showed that UMBO safely and repeatedly opened the BBB. BBB opening was confirmed visually and microscopically using Evans blue dye and magnetic resonance imaging. UMBO plus anti-PDL-1 was associated with a significant improvement of overall survival compared to anti-PD-L1 alone. Using mass spectroscopy, we showed that the penetration of therapeutic antibodies can be increased when delivered intravenously compared to non-sonicated brains. Furthermore, we observed an enhancement of activated microglia percentage when combined with anti-PD-L1. Here, we report that the combination of UMBO and anti-PD-L1 dramatically increases GL261-bearing mice's survival compared to their counterparts treated with anti-PD-L1 alone. Our study highlights the BBB as a limitation to overcome in order to increase the efficacy of anti-PD-L1 in GBM and supports clinical trials combining UMBO and in GBM patients.

7.
Can J Neurol Sci ; 50(2): 234-242, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35022089

RESUMO

BACKGROUND: Strategies to modulate the tumor microenvironment (TME) have opened new therapeutic avenues with dramatic yet heterogeneous intertumoral efficacy in multiple cancers, including glioblastomas (GBMs). Therefore, investigating molecular actors of TME may help understand the interactions between tumor cells and TME. Immune checkpoint proteins such as a Cluster of Differentiation 80 (CD80) and CD86 are expressed on the surface of tumor cells and infiltrative tumor lymphocytes. However, their expression and prognostic value in GBM microenvironment are still unclear. METHODS: In this study, we investigated, in a retrospective local discovery cohort and a validation TCGA dataset, expression of CD80 and CD86 at mRNA level and their prognostic significance in response to standard of care. Furthermore, CD80 and CD86 at the protein level were investigated in the discovery cohort. RESULTS: Both CD80 and CD86 are expressed heterogeneously in the TME at mRNA and protein levels. In a univariate analysis, the mRNA expression of CD80 and CD86 was not significantly correlated with OS in both local OncoNeuroTek dataset and TCGA datasets. CD80 and CD86 mRNA high expression was significantly associated with shorter progression free survival (PFS) (p < 0.05). These findings were validated using the TCGA cohort; higher CD80 and CD86 expressions were correlated with shorter PFS (p < 0.05). In multivariate analysis, CD86 mRNA expression was an independent prognostic factor for PFS in the TCGA dataset only (p < 0.05). CONCLUSION: CD86 could be used as a potential biomarker for the prognosis of GBM patients treated with immunotherapy; however, additional studies are needed to validate these findings.


Assuntos
Glioblastoma , Humanos , Prognóstico , Glioblastoma/diagnóstico , Glioblastoma/genética , Estudos Retrospectivos , Microambiente Tumoral , RNA Mensageiro/genética , RNA Mensageiro/metabolismo
8.
Adv Mater ; 35(1): e2207634, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36314408

RESUMO

Addressing the mechanical mismatch between biological tissue and traditional electronic materials remains a major challenge in bioelectronics. While rigidity of such materials limits biocompatibility, supramolecular polymer networks can harmoniously interface with biological tissues as they are soft, wet, and stretchable. Here, an electrically conductive supramolecular polymer network that simultaneously exhibits both electronic and ionic conductivity while maintaining tissue-mimetic mechanical properties, providing an ideal electronic interface with the human body, is introduced. Rational design of an ultrahigh affinity host-guest ternary complex led to binding affinities (>1013  M-2 ) of over an order of magnitude greater than previous reports. Embedding these complexes as dynamic cross-links, coupled with in situ synthesis of a conducting polymer, resulted in electrically conductive supramolecular polymer networks with tissue-mimetic Young's moduli (<5 kPa), high stretchability (>500%), rapid self-recovery and high water content (>84%). Achieving such properties enabled fabrication of intrinsically-stretchable stand-alone bioelectrodes, capable of accurately monitoring electromyography signals, free from any rigid materials.


Assuntos
Eletrônica , Polímeros , Humanos , Polímeros/química , Módulo de Elasticidade , Condutividade Elétrica , Hidrogéis/química
9.
Odontology ; 111(2): 409-419, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36175718

RESUMO

The purpose of this study was to evaluate the effect of adhesive sonic agitation on resin-dentin micro-tensile bond strength (µTBS) and interfacial morphology at the gingival wall of class-II cavity preparation. Seventy-two molars with prepared class-II cavities were divided into six groups (n = 12) according to the bonding mode; etch-and-rinse (E&R) or self-etch (SE) and application protocol of the universal adhesive (UA) employed (Clearfil Universal Bond Quick, Kuraray Noritake); following the manufacturer instructions (MI), manual agitation for 20 s (20s), or sonic agitation for 20 s using a modified sonic micro-brush mounted on EndoActivator device, Dentsply Sirona, (sonic). Restored teeth were sectioned into resin-dentin beams and slaps and µTBS was evaluated at 1 week (1w) and after thermocycling (10k). µTBS data were analyzed using the linear mixed-effects modeling with specific contrast (p < 0.05). The resin-dentin interfacial morphology was evaluated using a scanning electron microscope. Adhesive sonic agitation resulted in significantly higher µTBS means in both E&R and SE modes, compared to MI group. The µTBS of MI group showed significant reduction upon aging when applied in SE mode. Sonic agitation was associated with enhanced adhesive infiltration into dentin specially in E&R mode. Sonic agitation of UA using modified sonic micro-brush attached to EndoActivator device significantly improved the resin-dentin µTBS and interfacial morphology at the gingival wall of class-II cavity preparation.


Assuntos
Colagem Dentária , Cimentos Dentários , Adesivos Dentinários/química , Cimentos de Resina/química , Dentina , Resistência à Tração , Teste de Materiais
10.
Dent Mater ; 39(1): 70-85, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36481302

RESUMO

OBJECTIVES: To determine the bonding effectiveness of experimental 2-step universal adhesives (UAs) to high C-factor class-I cavity-bottom dentin and to assess the potential bond-strength contribution of an additional flowable composite layer. METHODS: Three experimental 2-step UA formulations, involving the application of a 10-MDP-based primer followed by a hydrophobic adhesive resin with a 15-to-20-µm film thickness and differing only for filler, referred to as BZF-21 (silica and bioglass filler), BZF-29 (silica filler) and BZF-29_hv (higher silica-filler loading resulting in a higher viscosity), all prepared by GC, along with three representative commercial adhesives, Clearfil SE Bond 2 (C-SE2, Kuraray Noritake), G-Premio Bond (G-PrB, GC) and OptiBond FL (Opti-FL, Kerr), were comparatively investigated for their 'immediate' and 'aged' (50,000 thermocycles) micro-tensile bond strength (µTBS), when applied either in etch-and-rinse (E&R) or self-etch (SE) mode, to high C-factor class-I cavity-bottom dentin (n = 10; 10 experimental groups). Four additional experimental groups involved the extra application of the flowable composite G-ænial Universal Flo (GC), employed as an intermediate liner in combination with the adhesives BZF-29 and G-PrB and again applied both in E&R or SE mode. Statistical analysis was performed using linear mixed-effects (LME) modelling and linear regression analysis (p < 0.05). RESULTS: All 2-step UAs performed similarly when compared to the gold-standard E&R Opti-FL and SE C-SE2 adhesives, except for the aged µTBS of BZF-29_hv applied in E&R mode, and significantly outperformed the 1-step UA G-PrB. Significant reduction in µTBS upon aging was only recorded for 2-step UAs applied in E&R mode. The extra flowable composite layer significantly improved G-PrB's µTBS. SIGNIFICANCE: The experimental 2-step UAs revealed favorable bonding performance in the challenging high C-factor class-I cavity model, comparable to that of the multi-step gold-standard E&R and SE adhesives and superior to that of the 1-step UA investigated. An additionally applied flowable composite layer compensated for the lower bonding effectiveness of the 1-step UA in the high C-factor cavity model.


Assuntos
Colagem Dentária , Cimentos Dentários , Adesivos Dentinários/química , Cimentos de Resina/química , Resinas Compostas/química , Resistência à Tração , Dentina , Teste de Materiais , Adesivos
11.
J Investig Med ; 70(7): 1466-1471, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35940732

RESUMO

Coagulopathy, cytokine release, platelet hyperactivity and endothelial activation are regarded as potential major contributors to COVID-19 morbidity. Complement activation might provide a bridge linking these factors in severe COVID-19 illness. In this study, we investigated the prognostic significance of selected complement factors in hospitalized patients with severe COVID-19 infection. The study included 300 hospitalized adults with severe COVID-19 infection. Complement factors (C3, C3a, C4, sC5b-9) were assessed by commercial ELISA kits. Outcome parameters included mortality, intensive care unit admission and duration of hospital stay. It was found that survivors had significantly higher serum C3 (median (IQR): 128.5 (116.3-141.0) mg/dL vs 98.0 (70.0-112.8) mg/dL, p<0.001) and C4 (median (IQR): 36.0 (30.0-42.0) mg/dL vs 31.0 (26.0-35.0) mg/dL, p<0.001) levels when compared with non-survivors. On the other hand, it was shown that survivors had significantly lower C3a (median (IQR): 203.0 (170.3-244.0) ng/mL vs 385.0 (293.0-424.8) ng/mL, p<0.001) and sC5b-9 (median (IQR): 294.0 (242.0-318.8) ng/mL vs 393.0 (342.0-436.5) ng/mL, p<0.001) levels when compared with non-survivors. Multivariate logistic regression analysis identified C3a (OR: 0.97 (95% CI 0.96 to 0.99), p<0.001) and C4 (OR: 0.92 (95% CI 0.86 to 0.98), p=0.011) levels as significant predictors of mortality. In conclusion, serum levels of complement factors are related to mortality in severely ill patients with COVID-19.


Assuntos
COVID-19 , Adulto , Citocinas , Hospitalização , Humanos , Fatores Imunológicos , Unidades de Terapia Intensiva , Prognóstico
12.
Materials (Basel) ; 15(3)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35160968

RESUMO

Contamination of zirconia restorations before cementation can impair the resin-zirconia bonding durability. The objective of this study was to evaluate the effect of human saliva or blood decontamination with 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP)-containing cleaner on the resin-zirconia shear bond strength (SBS). METHODS: A total of 220 zirconia specimens were prepared and air-abraded and randomly distributed into 11 groups (n = 20 per group). Except for the control group (no contamination), zirconia specimens were contaminated with either human saliva (five groups) or blood (five groups), and then subjected to one of five cleaning methods: water rinsing, 38% phosphoric acid etchant (Pulpdent Corp., Watertown, MA, USA), 70% isopropanol alcohol (Avalon Pharma, Riyadh, Saudi Arabia), Ivoclean (Ivoclar Vivadent, Schaan, Lichtenstein) and Katana Cleaner (Kuraray Noritake, Tokyo, Japan). The resin-zirconia SBS was tested at 24 h and after thermocycling (10 k cycles). Three-way ANOVA followed by Tukey's multiple comparisons test were utilized to analyze the SBS data. Failure modes were evaluated using a scanning electron microscope. RESULTS: Both blood and saliva significantly affected resin-zirconia SBS as contaminants. After thermocycling, there was no statistically significant difference between SBS obtained after decontamination with the Katana Cleaner (blood, 6.026 ± 2.805 MPa; saliva, 5.206 ± 2.212 MPa) or Ivoclean (blood, 7.08 ± 3.309 MPa; saliva, 6.297 ± 3.083 MPa), and the control group (no contamination, 7.479 ± 3.64 MPa). Adhesive and mixed failures were the most frequent among the tested groups. CONCLUSION: Both 10-MDP-containing cleaner (Katana Cleaner) and zirconium oxide-containing cleaner (Ivoclean) could eliminate the negative effect of saliva and blood contamination on resin-zirconia SBS.

13.
Middle East J Dig Dis ; 14(4): 473-477, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37547505

RESUMO

Bile duct injury (BDI) is a severe and sometimes life-threatening complication of cholecystectomy. Several series have described a 0.5% to 0.6% incidence of BDI during laparoscopic cholecystectomy. We received an emergency call from the operating theater by the surgery team to assess an iatrogenic BDI in a 58-year-old man with cirrhosis who presented for laparoscopic cholecystectomy. After many trials by endoscopic retrograde cholangiopancreatography (ERCP) the guide wire passed to the peritoneal cavity and failed to pass proximally. Laparoscopy resumed, and the surgeon tried to pass the flexible guide wire proximally unsuccessfully. Then, a decision to hold the sphincterotome by laparoscopy and passing it proximally in harmony with ERCP was taken, which was successful. A regular ERCP with 10F plastic stent insertion was carried out, and the perforation was secured by the inserted stent without any further surgical intervention. Laparoscopy-assisted ERCP may give new insights into the immediate repair of iatrogenic bile duct injuries.

14.
Dent Mater ; 37(5): 894-904, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33757655

RESUMO

OBJECTIVE: Incorporating silane-coupling agent into universal adhesives (UAs) to simplify adhesive luting of glass-ceramic restorations appeared ineffective due to silane's instability in an acidic aqueous solution. This study aimed to evaluate new silane technology added to an experimental UA to be bonded to glass ceramics without separate prior silanization. METHODS: Combined silane technology, consisting of 3-(aminopropyl)triethoxysilane (APTES) and γ-methacryloxypropyltriethoxysilane (γMPTES), was incorporated into an experimental UA formulation, being referred to as ADH-XTE (3M Oral Care). Immediate and aged shear bond strength (SBS) of ADH-XTE onto as-milled ('AM'), tribochemical silica-coated ('TSC'), HF-etched ('HF'), and mirror-polished ('MP') glass-ceramic CAD/CAM blocks (IPS e.max CAD) with/without separate silanization was measured (n = 10/group). The control adhesives included Scotchbond Universal ('SBU') and Scotchbond 1 XT ('SB1-XT'). The glass-ceramic surface topography and the fractography of the SBS-debonded specimens were observed by SEM. RESULTS: Without separate prior silanization, the experimental UA ADH-XTE, containing combined APTES/γMPTES silane technology, significantly outperformed the glass-ceramic bonding efficiency of its silane-containing SBU precursor, while it performed equally effective as SBU applied with prior silanization. Upon aging, significant reduction in SBS was recorded when ADH-XTE was bonded to TSC glass-ceramic surfaces (p < 0.05), while not to HF ones. Notably, the lowest SBS was obtained when the UAs were bonded to AM and MP glass-ceramic surfaces, in particular when applied without separate prior silanization (p < 0.05). SIGNIFICANCE: The glass-ceramic bonding capacity of the new combined APTES/γMPTES silane-containing UA ADH-XTE surpassed that of its SBU precursor. HF etching remains needed to durably bond to glass-ceramics.


Assuntos
Colagem Dentária , Silanos , Cerâmica , Cimentos Dentários , Porcelana Dentária , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Tecnologia
15.
J Adhes Dent ; 22(5): 483-501, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33073780

RESUMO

PURPOSE: Universal adhesives (UAs) are applied in 2-step etch-and-rinse (2-E&R) or 1-step self-etch (1-SE) mode. This study investigated whether three UAs could benefit from a highly filled extra bonding layer (EBL), turning them into 3-E&R and 2-SE UAs, respectively, thus also compensating for the commonly thin film thickness of UAs. MATERIALS AND METHODS: Microtensile bond strength (µTBS) to bur-cut dentin of Clearfil Universal Bond Quick (C-UBq, Kuraray Noritake), G-Premio Bond (G-PrB, GC) and Prime&Bond Active (P&Ba, Dentsply Sirona), applied in E&R and SE mode without/with the adhesive resin (EBL) of OptiBond FL (Opti-FL_ar, Kerr), was compared to that of the 3-E&Ra OptiBond FL (Opti-FL; Kerr), which was also employed in 2-SE mode. As a cross reference, the SE primer of Clearfil SE Bond 2 (Kuraray Noritake) was combined with Opti-FL_ar (C-SE2/Opti-FL) and again applied in 2-SE and 3-E&R mode. µTBS was measured after 1 month of water storage (37°C) and additional 25,000 and 50,000 thermocycles (TC). All µTBS were statistically analyzed using three different linear mixed-effects models with specific contrasts (p < 0.05). RESULTS: Overall, the four parameters (adhesive, bonding mode, aging, EBL) significantly influenced µTBS. G-PrB and P&Ba benefited from EBL when applied in both E&R and SE bonding modes. In E&R mode, P&Ba generally revealed the highest µTBS; C-UBq presented an intermediate and G-PrB the lowest µTBS. No significant differences were found between different bonding modes. C-SE2/Opti-FL outperformed Opti-FL in 3-E&R and 2-SE_1 month/25k. CONCLUSION: The overall benefit of EBL on the 1-month and TC-aged bonding efficacy differed for the different UAs tested.


Assuntos
Colagem Dentária , Adesivos Dentinários , Cimentos Dentários , Dentina , Teste de Materiais , Resistência à Tração
16.
ACS Appl Mater Interfaces ; 12(27): 30120-30135, 2020 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-32530270

RESUMO

Apart from producing high bond strength to tooth enamel and dentin, a dental adhesive with biotherapeutic potential is clinically desirable, aiming to further improve tooth restoration longevity. In this laboratory study, an experimental two-step universal adhesive, referred to as Exp_2UA, applicable in both the etch-and-rinse (E&R) and self-etch (SE) modes and combining a primer, containing 10-methacryloyloxydecyldihydrogen phosphate as a functional monomer with chemical binding potential to hydroxyapatite, with a bioglass-containing hydrophobic adhesive resin, was multifactorially investigated. In addition to primary property assessment, including measurement of bond strength, water sorption, solubility, and polymerization efficiency, the resultant adhesive-dentin interface was characterized by transmission electron microscopy (TEM), the filler composition was analyzed by energy-dispersive X-ray spectroscopy, and the bioactive potential of the adhesive was estimated by measuring the long-term ion release and assessing its antienzymatic and antibacterial potential. Four representative commercial adhesives were used as reference/controls. Application in both the E&R and SE modes resulted in a durable bonding performance to dentin, as evidenced by favorable 1 year aged bond strength data and a tight interfacial ultrastructure that, as examined by TEM, remained ultramorphologically unaltered upon 1 year of water storage aging. TEM revealed a 20 µm thick hydrophobic adhesive layer with a homogeneous bioglass filler distribution. Adequate polymerization conversion resulted in extremely low water sorption and solubility. In situ zymography revealed reduced endogenous proteolytic activity, while Streptococcus mutans biofilm formation was inhibited. In conclusion, the three-/two-step E&R/SE Exp_2UA combines the high bonding potential and bond degradation resistance with long-term ion release, rendering the adhesive antienzymatic and antibacterial potential.


Assuntos
Antibacterianos/química , Cálcio/química , Fluoretos/química , Compostos de Zinco/química , Antibacterianos/farmacologia , Biofilmes/efeitos dos fármacos , Adesivos Dentinários , Teste de Materiais , Microscopia Eletrônica de Transmissão , Cimentos de Resina/química , Streptococcus mutans/efeitos dos fármacos , Resistência à Tração
18.
JGH Open ; 4(2): 280-283, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32280778

RESUMO

Bilharziasis (Schistosomiasis) is the third devastating tropical disease globally and is endemic in many countries including Egypt. The pathology of chronic colonic schistosomiasis results from egg-induced immune response, granuloma formation, and associated fibrotic changes that may manifest as bloody diarrhea, cramping, and, eventually, inflammatory colonic polyposis. Huge polyps complicating schistosomiasis are not frequently reported in the literature. Also, huge polyps as a sole manifestation of intestinal bilharziasis are rather rarely reported. Here, we report an Egyptian male patient who presented with bleeding per rectum with a huge polyp on colonoscopy, with morphological traits that mimicked colon cancer and proved to be of bilharzial etiology after surgical excision.

19.
J Adhes Dent ; 22(1): 65-77, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32030377

RESUMO

PURPOSE: This study investigated the bonding efficacy of a new so-called self-adhesive composite hybrid onto flat (FLAT) and high C-factor class-I cavity-bottom (CAVITY) dentin. MATERIALS AND METHODS: The immediate and aged (50,000 thermocycles) microtensile bond strength (µTBS) to FLAT and CAVITY dentin of the experimental self-adhesive bulk-fill restorative (K-0180 ASAR pilot [ASAR-pilot], Dentsply Sirona) was compared to that of two universal adhesives applied in self-etch mode and combined with a bulk-fill composite (Prime&Bond Elect/QuiXfil [P&Be/QuiXF], Prime&Bond Active/QuiXfil [P&Ba/QuiXF], both Dentsply Sirona), two pre-conditioned materials (Activa Bioactive-Restorative [Activa], Pulpdent; Fuji II LC Improved [Fuji2LC], GC); and one bulk-fill glass-hybrid restorative (Equia Forte Fil [EquiaF], GC). Statistically significant differences were recorded using Welch's ANOVA with Games-Howell contrast (p < 0.05). RESULTS: No significant difference in immediate µTBS was recorded when the restorative materials were applied onto FLAT dentin, except for Activa_FLAT and EquiaF_FLAT. When bonded to CAVITY dentin, the significantly highest µTBS was recorded for Fuji2LC_CAVITY (layer filled), and was not significantly different only from P&Ba/QuiXF_CAVITY. Upon aging, the highest µTBS to flat dentin was achieved by ASAR-pilot_FLAT, which was not significantly different from P&Be/QuiXF_FLAT and Fuji2LC_FLAT. No significant difference between immediate and aged µTBS was recorded for ASAR-pilot when bonded onto FLAT or CAVITY dentin; the latter, however, was associated with low bond strength. CONCLUSION: Favorable bonding performance was found for the new self-adhesive bulk-fill composite hybrid ASAR-pilot when bonded to flat dentin. However, much lower bond strength was recorded when ASAR-pilot was bonded to high C-factor cavity-bottom dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Dentina , Teste de Materiais , Cimentos de Resina , Resistência à Tração
20.
J Adhes Dent ; 22(1): 85-97, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32030379

RESUMO

PURPOSE: The material structure and chemical elemental composition of a new self-adhesive composite hybrid were investigated. The bonding performance when applied on flat (FLAT) vs high C-factor class-I cavity-bottom (CAVITY) dentin and in light-cure (LC) vs self-cure (SC) mode was determined. MATERIALS AND METHODS: The self-adhesive bulk-fill composite Surefil One (Su-O; Dentsply Sirona) was compared with the resin-modified glass-ionomer Fuji II LC Improved (Fuji2LC; GC) and the ion-releasing alkasite material Cention N (CentionN; Ivoclar Vivadent). The material structure was examined with SEM and TEM, while the chemical elemental composition was analyzed using EDS. The immediate and aged microtensile bond strength (µTBS) of Su-O_LC/SC was compared to that of Fuji2LC applied without any pre-treatment, and to that of CentionN applied following bonding with Adhese Universal (AU) (Ivoclar Vivadent) in self-etch mode (AU/CentionN). All restorative materials were bonded onto FLAT and CAVITY dentin. Statistical analysis was performed with the Kruskal-Wallis nonparametric test. RESULTS: EDS analysis revealed that Su-O was richer in C and P than the reference restorative materials. Applied to FLAT dentin, the significantly highest immediate and aged µTBS were recorded for AU/CentionN, which were not significantly different only from Su-O_LC. Applied to CAVITY dentin, the significantly highest immediate µTBS was recorded for AU/CentionN, which did not differ significantly only from Su-O_SC. Su-O_LC bonded to CAVITY dentin suffered from a high incidence of pre-test failures. CONCLUSION: While Su-O_LC bonded effectively and durably to FLAT dentin, Su-O_SC bonded more favorably than Su-O_LC in class-I cavities, which was probably related to shrinkage stress variously challenging the respective bond.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Dentina , Teste de Materiais , Cimentos de Resina , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...